TRAVELLERS HIGH POWER |
||
|
|
The Travellers with high power laser diodes
Travellers is an automatic scanning laser combining a visible laser and an high power infrared laser Automatic power supply from 90 to 270 V Dimensions: height 180 cm; base 50 x 50cm, weight 50 kgs Body: metal with 180° column rotation Manual adjustment of beam incidence Time and frequency digital programming Automatic scanning parameters programming Apparatus movable by its handle ( not shown) 600µm high efficiency silica optical fibre Warranty: factory 1 years parts and labor The inner volume and the possibility to integrate cooling systems ( air or water) ensure the equipment aptitude for continuous use all day long. This device is designed for a high daily treatment use. |
|
The
different models TV 1000 + 5000 ( 1W visible + 5W IR ) TV 500 + 15000 ( 500mW visible + 15W IR ) TV
1000
+ 15000 ( 1W visible
+ 15W IR )
High power laser emitters are temperature monitored for ensuring a long lifetime
and constant results
The visible and IR beams are mixed in one beam to ensure higher quality results, either in scanning or in fiber modes
NB: Other wavelenghts and powers upon request |
||
| TRAVELLERS CO2 ( defocused )
Identical body dimensions, but weight 100kgs
Equipped with a red aiming laser beam; the CO2 laser being invisible, as well as protection for patient and doctor.
Active beam: CO2 laser beam, wavelenght 10600nm Power variable from 1 to 15 Watts or 25 Watts Same digital programming for time and frequency Same automatic scanning parameters This device doesn't come with an optical fiber, because the CO2 cannot pass through a silica fiber, but we have special CO2 guides on request.
The Device is equipped with a "patient security breaker", then the patient can stop the laser whenever he wants.
|
Why
different wavelenghts for treatment ?
We have 2 wavelenght ranges:
1: absorption by the proteins in the visible and near IR range ( also called VISIR)
2: absorption by water ( very strong ) in the long IR range, as for the CO2 laser
Generally, studies make appear good and fast results on the acute diseases with the VISIR lasers, and we have consistent effects on chronic and large area diseases with the CO2 lasers.
The direct penetration depth is of few centimeters with the VISIR lasers, versus the etiology of the problem, and just 1 to 2 mm for the CO2 lasers. Explanation is that watre, main component of the body, is a vector for the CO2 laser and thus the effect can reach deep tissues indirectly.
We have the concept of depth penetration and depth action, following the interaction energy / living matter. |
|
|
biophoton 35 rue leon blum 31140 Saint Alban France tel: 33 5 61 70 34 55 fax: 33 5 61 70 35 65 info@biophoton.fr |
||