TRAVELLERS  HIGH  POWER

   

The Travellers with high power laser diodes

 

Travellers is an automatic scanning laser combining a visible

laser and an high power infrared laser

Automatic power supply from 90 to 270 V

Dimensions: height 180 cm; base 50 x 50cm, weight 50 kgs

Body: metal with 180° column rotation

Manual adjustment of beam incidence

Time and frequency digital programming

Automatic scanning parameters programming

Apparatus movable by its handle ( not shown)

600µm high efficiency silica optical fibre

Warranty: factory 1 years parts and labor

The inner volume and the possibility to integrate cooling systems

( air or water) ensure the equipment aptitude for continuous use

 all day long.

This device is designed for a high daily treatment use.

The different models

TV 500   +   5000        ( 500mW visible +   5W IR )

TV 1000 +   5000        ( 1W        visible +   5W IR )

TV 500   + 15000        ( 500mW visible + 15W IR )

TV 1000 + 15000        ( 1W        visible + 15W IR )

 

High power laser emitters are temperature monitored

for ensuring a long lifetime and constant results

 

The visible and IR beams are mixed in one beam to ensure

higher quality results, either in scanning or in fiber modes

 

NB: Other wavelenghts and powers upon request

TRAVELLERS CO2 ( defocused )

 

Identical body dimensions, but weight 100kgs

 

Equipped with a red aiming laser beam; the CO2 laser being invisible, as well as protection for patient and doctor.

 

Active beam: CO2 laser beam, wavelenght 10600nm

Power variable from 1 to 15 Watts or 25 Watts

Same digital programming for time and frequency

Same automatic scanning parameters

This device doesn't come with an optical fiber, because the CO2 cannot pass through a silica fiber, but we have special CO2 guides on request.

 

The Device is equipped with a "patient security breaker", then the patient can stop the laser whenever he wants.

 

 

CO2 Protocols

please click

Why different wavelenghts for treatment ?

We have 2 wavelenght ranges:

 

1: absorption by the proteins in the visible and near IR range ( also called  VISIR)

 

2: absorption by water ( very strong ) in the long IR range, as for the CO2 laser

 

Generally, studies make appear good and  fast results on the acute diseases with the VISIR lasers, and we have consistent effects on chronic and large area diseases with the CO2 lasers.

 

The direct penetration depth is of few centimeters with the VISIR lasers, versus the etiology of the problem, and just 1 to 2 mm for the CO2 lasers.

Explanation is that watre, main component of

 the body, is a vector for the CO2 laser and thus the effect can reach deep tissues indirectly.

 

We have the concept of depth penetration and depth action, following the interaction

energy / living matter.

 

biophoton 35 rue leon blum 31140 Saint Alban France tel:  33 5 61 70 34 55   fax: 33 5 61 70 35 65   info@biophoton.fr